*** Price includes 2 sensors ***

Universal temperature switch for heating, cooling and temperature monitoring. Many possibilities, e.g. for temperature monitoring, thanks to 4 potential-free switching contacts.
The display shows switch-on and switch-off temperatures, current (measured) temperatures, set parameters and minimum/maximum values. The latter is the memory for the highest and lowest measured temperature.

Applications

Switches cooling and heating

Based on the set switch-on and switch-off temperatures, the controller determines whether heating or cooling is performed.
This temperature switch has separate contacts, suitable for switching 230 V and monitoring temperature limits.

Alarm function for temperature monitoring

The temperature switch can trigger an alarm if the measured temperature goes outside the set range. You can set a delay time for this, up to a maximum of 8 hours. This function is useful, for example, for temperature monitoring in a stable or animal housing.
Each channel has its own relay for alarms. For example, to monitor tracing pipes for frost protection. The built-in buzzer can also be used for this purpose (according to your choice).

Digital thermometer and energy saving

This temperature controller can also be used as a 2-channel temperature gauge (digital thermometer), e.g. for cooling and storage.
Another application is energy saving for a domestic hot water circulation pump, by measuring the temperature on inlet and outlet boiler pipe. The pump will then only run when hot water is requested.

Temperature switch 7 basic functions

1.    Digital temperature gauge for channel 1
2.    Digital temperature gauge for channel 1 + 2
3.    Temperature switch on channel 1
4.    Temperature switch on channel 1 + 2
5.    Temperature differential control
6.    Control for circulation pump
7.    Manual (other applications)
* channel 3, 4, 5 is with alarm function.

2-channel temperature switch

•    Faaie plastic housing, intended for wall mounting
•    This control contains 4 switching contacts of 5 amps each
•    3 LEDs per channel: switching contact, alarm contact and fault
•    Sensors with metal end, also suitable as pipe sensors
•    Sensor connection wires may be extended up to 50 metres
•    Fault message in case of interrupted or short-circuited sensor

Wide temperature range

Switching is possible at any temperature within the range from -55 to +125 °C. Between -10 and + 85 °C, this controller is accurate to half a degree.

Set temperatures remain in memory if the mains voltage is lost.

Specifications

•    Dimensions: 160 x 120 x 63 mm
•    Including: 5x cable gland (cable entry)
•    Connected load: 3,000 W
•    Output: 4x potential-free relay 5A
•    Relay contacts: NO/NC = changeover
•    Connection voltage: 230 Volt
•    Internal consumption: approx. 3 W
•    Measuring range: -55...+125 °C
•    Resolution: steps of 0.1 °C
•    Switching hysteresis: freely adjustable
•    Operation: via 4 push buttons
•    Input for sensors: 2x RJ45
•    Sensor connection wire: 2 m
•    LCD display: 60 x 15 mm
•    Indicator lights: 6x LED
•    Safety class: IP20
•    Manual: German
•    Quality mark: CE

Delivery includes two (2) sensors
NB: basic knowledge of electrical and control engineering is required to connect and commission this product.
Alternative: temperature differential switch.

 

Order by:

Add review
Patrick - 17-05-2016 20:30

Ik gebruik deze temperatuur-schakelaar om een circulatiepomp te schakelen tussen mijn gasboiler en mijn zonneboiler.
Als het water in de zonneboiler 5° warmer is dan het water in de gasboiler, slaat de pomp aan. Als de temp. gelijk is of hoger slaat de pomp uit.
Op die manier kan ik een groter volume opwarmen met de zonnecollector en heb ik hier dus meer rendement van.
In plaats van enkel de 250L van de zonneboiler, warm ik zo (op zonnige dagen) ook de 100L van de gasboiler op.
Hierdoor kan ik de gasinstallatie volledig afzetten vanaf april tot (hopelijk) oktober.

This website uses cookies to measure visits, we do not store any personal data.
Accept selected cookies Reject cookies